CUMMINS Home Standby Generator Set Instalační manuál

Procházejte online nebo si stáhněte Instalační manuál pro Generátory energie CUMMINS Home Standby Generator Set. CUMMINS Home Standby Generator Set Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 100
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Installation Manual
Home Standby Generator Set
GSBB (Spec A)
English - Original Instructions 4-2010 A029V088 (Issue 2)
Zobrazit stránku 0
1 2 3 4 5 6 ... 99 100

Shrnutí obsahu

Strany 1 - Installation Manual

Installation ManualHome Standby Generator SetGSBB (Spec A)English - Original Instructions 4-2010 A029V088 (Issue 2)

Strany 2

2. Introduction 4-201060 Hz 50 HzPropane Vapor Natural Gas Propane Vapor Natural GasOperating Temperature RangeBelow 20 °F (-7 °C) Additional oil heat

Strany 3 - Table of Contents

Cummins Power Generation1400 73rd Ave. NEMinneapolis, MN 55432 USAPhone 1 763 574 5000Toll-free 1 800 888 6626Fax 1 763 574 5298Copyright © 2010 Cummi

Strany 4 - Table of Contents 4-2010

4-2010 2. Introduction60 Hz 50 HzPropane Vapor Natural Gas Propane Vapor Natural GasOil Capacity Approximately 80 oz (2.3 Liters)Oil Recommendation 0W

Strany 5 - 1.2 General Precautions

2. Introduction 4-20102.3 Information For After InstallationWARNING: Improper installation can result in severe personal injury, death and damageto eq

Strany 6 - 1.6 Batteries Can Explode

3 Step-By-Step Outline of InstallationWARNING: The installer is responsible for complying with all applicable installationcodes and safety requirement

Strany 7 - A029V088 (Issue 2) 3

3. Step-By-Step Outline of Installation 4-20103.1.1 Installation Codes and Standards for SafetyWARNING: The generator set installer bears sole respons

Strany 8 - 4 A029V088 (Issue 2)

4-2010 3. Step-By-Step Outline of InstallationAppropriately-sized junction box and cover for heater/GFCI wiring (if installing). XProvided on cold wea

Strany 9 - 2 Introduction

3. Step-By-Step Outline of Installation 4-20103.1.2.2 Tools RequiredUse a forklift to move the generator set and set it in place. Alternatively, a one

Strany 10 - 6 A029V088 (Issue 2)

4-2010 3. Step-By-Step Outline of InstallationRSS 200-6869 XNOTE: Model RSS 100-6634 and RSS 200-6635 transfer switches do not incorporatea utility ci

Strany 11 - A029V088 (Issue 2) 7

3. Step-By-Step Outline of Installation 4-2010FIGURE 3. PARTIAL COVERAGE LOAD CONNECTIONS (TRANSFER SWITCH WITH CONTROLLER)FIGURE 4. FULL COVERAGE LOA

Strany 12 - 8 A029V088 (Issue 2)

4-2010 3. Step-By-Step Outline of InstallationGenerator set location is critical for safety and good performance. Follow the guidelines below:· Instal

Strany 14 - 3.1.2.1 Materials Required

3. Step-By-Step Outline of Installation 4-2010FIGURE 5. GENERATOR SET CLEARANCES3.3 Preparing the SiteSteps to preparing a proper/safe generator set s

Strany 15 - A029V088 (Issue 2) 11

4-2010 3. Step-By-Step Outline of InstallationSet the generator set in place and pound the four corner stakes into the ground to secure thegenerator s

Strany 16 - 3.1.2.2 Tools Required

3. Step-By-Step Outline of Installation 4-20103.6.1 AC Power Supply ConnectionsWARNING: Electrical connections must be made by a licensed electrician.

Strany 17 - A029V088 (Issue 2) 13

4-2010 3. Step-By-Step Outline of InstallationFIGURE 7. TYPICAL SYSTEM GROUNDING ONE-LINE DIAGRAMS3.6.3 Automatic Transfer SwitchThe model GSBB genera

Strany 18 - 14 A029V088 (Issue 2)

3. Step-By-Step Outline of Installation 4-20103.6.3.1 Transfer Switch Communications WiresWARNING: Interconnecting the generator set and the public ut

Strany 19 - A029V088 (Issue 2) 15

4-2010 3. Step-By-Step Outline of Installation3. Mount the operator panel with four No. 6 wood screws or wall anchors.· On brick, stone or block walls

Strany 20 - 3.3 Preparing the Site

3. Step-By-Step Outline of Installation 4-2010No. Description No. Description1 NC 2 Load control pin 8 or 93 Ground pin 4 4 From thermostat5 To air co

Strany 21 - A029V088 (Issue 2) 17

4-2010 3. Step-By-Step Outline of InstallationNo. Description No. Description1 NC 2 Load Control Pin 8 or 93 Ground Pin 4 4 From Circuit Breaker5 To L

Strany 22 - 3.6.2 Grounding

3. Step-By-Step Outline of Installation 4-2010No. Description No. Description1 NC 2 Load Control Pin 8 or 93 Ground Pin 4 4 From Circuit Breaker5 To L

Strany 23 - A029V088 (Issue 2) 19

4-2010 3. Step-By-Step Outline of InstallationAn optional thermostatically controlled battery heater is available for more reliable starting inambient

Strany 24 - 3.6.5 Operator Panel

Table of Contents1. IMPORTANT SAFETY INSTRUCTIONS ... 11.1 Save The

Strany 25 - A029V088 (Issue 2) 21

3. Step-By-Step Outline of Installation 4-2010In all fuel system installations, cleanliness is extremely important.· Make every effort to prevent fuel

Strany 26 - · Mounting: No restrictions

4-2010 3. Step-By-Step Outline of InstallationCallout ComponentNumber12 Fuel Connection (Female) 3/4 NPT & NG & LPV13 4x Anchoring SpikeFIGURE

Strany 27

3. Step-By-Step Outline of Installation 4-2010See the Generator Set Specifications Table for fuel specifications, such as BTU. Todetermine the require

Strany 28 - 3.6.8 Battery

4-2010 3. Step-By-Step Outline of InstallationTABLE 20. NATURAL GAS PIPE CAPACITY - CUBIC FEET OF GAS PER HOURNormal Iron Length of Pipe in FeetPipe S

Strany 29 - 3.7 Fuel System

3. Step-By-Step Outline of Installation 4-2010TABLE 21. REQUIRED PROPANE TANK SIZE IN GALLONS (LITERS) FOR INDICATEDTEMPERATURES WHEN KEPT AT LEAST HA

Strany 30 - 3.7.1 Fuel Line Connections

4-2010 3. Step-By-Step Outline of InstallationTABLE 22. PROPANE VAPOR PIPE CAPACITY - CUBIC FEET OF GAS PER HOURNominal Iron Length of Pipe in FeetPip

Strany 31 - 3.7.3 Natural Gas Fuel System

3. Step-By-Step Outline of Installation 4-2010After assembly, and before initial operation, all fuel system connections, hose valves, regulatorsand fi

Strany 32 - 28 A029V088 (Issue 2)

4 Optional Internet/Email InterfaceDescriptions4.1 IntroductionThis feature allows for in-home or remote access to your generator set through a web pa

Strany 33 - 3.7.4 Propane Fuel System

4. Optional Internet/Email Interface Descriptions 4-20104.2 Screen DescriptionsFIGURE 15. HOME PAGE4.2.1 Setting Time and DateSelect the Genset Time/D

Strany 34 - 30 A029V088 (Issue 2)

4-2010 4. Optional Internet/Email Interface Descriptions4.2.2 Set Exercise ScheduleSelect the Exercise Schedule Tab on the Home Screen to set the gene

Strany 35 - A029V088 (Issue 2) 31

Table of Contents 4-20106.2 In-Home Network Access to the Generator Set ... 426.3 Setti

Strany 36 - 3.8 Engine Exhaust

4. Optional Internet/Email Interface Descriptions 4-2010FIGURE 19. EVENT LOG4.2.5 Fault LogSelect the Fault Log Tab on the Home Screen to review the l

Strany 37 - Descriptions

4-2010 4. Optional Internet/Email Interface DescriptionsFIGURE 22. NETWORK SETUP PARAMETERS4.2.7 Email Setup Screen DescriptionsThe user must determin

Strany 38 - 4.2 Screen Descriptions

4. Optional Internet/Email Interface Descriptions 4-2010FIGURE 25. SAVE SCREEN38 A029V088 (Issue 2)

Strany 39 - 4.2.4 Event Log

5 Ethernet Connection InstallationWorksheet:NOTE: IMPORTANT: Leave a filled-out copy of this sheet (chapter) with the customerfor future reference.Thi

Strany 40 - 4.2.5 Fault Log

5. Ethernet Connection Installation Worksheet: 4-20105.3.2 Email/Internet Service Provider (ISP)DSL, Cable, Satellite, etc.This will support Email Not

Strany 41 - 4.2.8 Saving Changes

6 Optional Internet/Email Interface Setup6.1 Ethernet Connections (Optional)Wiring connections to the Ethernet RJ-45 plug are shown in the Ethernet RJ

Strany 42 - FIGURE 25. SAVE SCREEN

6. Optional Internet/Email Interface Setup 4-2010FIGURE 28. NETWORK CONNECTIONS6.2 In-Home Network Access to the Generator Set1. Connect an Ethernet c

Strany 43 - Worksheet:

4-2010 6. Optional Internet/Email Interface SetupPassword: CumminsThe following screen will be displayed after a few seconds.NOTE: It may take a few s

Strany 44 - 40 A029V088 (Issue 2)

6. Optional Internet/Email Interface Setup 4-2010FIGURE 30. NETWORK SETUP SCREEN ON THE IN-HOME OPERATOR PANELFIGURE 31. NETWORK SETUP SCREENFIGURE 32

Strany 45 - FIGURE 26. ETHERNET CONNECTOR

4-2010 6. Optional Internet/Email Interface Setup3. Click Click here to start Network Setup.4. Set up in-home computer access to the generator set.5.

Strany 46 - 42 A029V088 (Issue 2)

1 IMPORTANT SAFETY INSTRUCTIONS1.1 Save These InstructionsThis manual contains important instructions for the generator set that should be followed du

Strany 47 - FIGURE 29. GENERATOR SET HOME

6. Optional Internet/Email Interface Setup 4-2010FIGURE 34. NETWORK SETUP SCREENFIGURE 35. NETWORK SETUP PARAMETERSFIGURE 36. EMAIL SETUP PARAMETERSFI

Strany 48 - 44 A029V088 (Issue 2)

4-2010 6. Optional Internet/Email Interface Setup6.5 Remote Internet Access to the Generator SetWARNING: Opening ports in your firewall can pose netwo

Strany 49 - 6.4 Email Setup Parameters

6. Optional Internet/Email Interface Setup 4-2010Answer: Yes, a router or switch is required to allow for the connection of more than one device(compu

Strany 50 - FIGURE 37. EMAIL ADDRESSES

4-2010 6. Optional Internet/Email Interface SetupAnswer: Static IP addresses are required if you plan to access your generator set remotely viathe Int

Strany 51 - 6.6 Help Hotline

6. Optional Internet/Email Interface Setup 4-2010This page is intentionally blank.50 A029V088 (Issue 2)

Strany 52 - 48 A029V088 (Issue 2)

7 Operation7.1 3 Position SwitchA three-position Start/Stop switch is located at the genset control panel.Switch positions available:· Manual Start: N

Strany 53 - A029V088 (Issue 2) 49

7. Operation 4-20107.2 In-Home Operator PanelThe operator panel must be hard-wired to the generator set in order for the generator system tooperate.NO

Strany 54 - 50 A029V088 (Issue 2)

4-2010 7. Operation7.3 Typical OperationNOTE: The following diagrams are based on an APPROXIMATE time duration. Yourgenset may vary slightly from the

Strany 55 - 7 Operation

7. Operation 4-2010FIGURE 42. EXERCISE TIMING DIAGRAM54 A029V088 (Issue 2)

Strany 56 - 7.2 In-Home Operator Panel

4-2010 7. OperationFIGURE 43. MANUAL START/STOP TIMING DIAGRAMA029V088 (Issue 2) 55

Strany 57 - 7.3 Typical Operation

1. IMPORTANT SAFETY INSTRUCTIONS 4-2010· This standby generator set and the public utility may only be connected to the housecircuits by means of the

Strany 58 - 54 A029V088 (Issue 2)

7. Operation 4-2010FIGURE 44. LOAD MANAGEMENT TIMING DIAGRAM7.3.1 Normal Operation: Utility Power Available and ConnectedAs long as utility power is a

Strany 59 - A029V088 (Issue 2) 55

4-2010 7. OperationFIGURE 45. UTILITY PRESENT AND CONNECTED—STANDBY OFF LAMP ON7.3.2 Emergency Operation: Utility Power InterruptedIf utility power is

Strany 60 - 56 A029V088 (Issue 2)

7. Operation 4-20107.4 To Enable/Disable StandbyNormally, you should not have to disable generator set STANDBY.· STANDBY should always be enabled (ON)

Strany 61 - A029V088 (Issue 2) 57

4-2010 7. Operation2. Press START to manually start the generator set and connect it to supply power to thehouse. The STANDBY OFF lamp will come on an

Strany 62 - 7.4 To Enable/Disable Standby

7. Operation 4-2010· Perform the maintenance.Press the BACK button to return to the home screen.FIGURE 50. TYPICAL MAINTENANCE DUE SCREEN7.6.3 New Eve

Strany 63 - 7.6.2 Maintenance Due Screen

4-2010 7. OperationFIGURE 52. GENERATOR SET STATUS SCREEN7.8 Display Setup and Software Info7.8.1 Brightness and ContrastTo change the Brightness and

Strany 64 - 7.7 Genset Status

7. Operation 4-2010FIGURE 53. DISPLAY SETUP AND SOFTWARE INFO SCREENS7.8.2 Software InfoTo check on the generator set and display software:1. Press th

Strany 65 - 7.8.1 Brightness and Contrast

4-2010 7. Operation5. Press the BACK button to return to the home screen.7.9 Event Log7.9.1 To Check Log of Last 20 Events1. Press the MENU button on

Strany 66 - 7.8.2 Software Info

7. Operation 4-2010· "Genset exercise completed"· "Genset started due to loss of utility"· "Genset stopped with return of uti

Strany 67 - 7.9 Event Log

4-2010 7. OperationFIGURE 55. FAULT LOG SCREEN7.11 Exercise SettingsTo set the generator set exercise schedule:1. Press the EXCER button on the home s

Strany 68 - 7.10 Fault Log

4-2010 1. IMPORTANT SAFETY INSTRUCTIONS· To prevent arcing when disconnecting the battery:· Move the Stop Switch (S2) to the Stop position, disconnect

Strany 69 - 7.11 Exercise Settings

7. Operation 4-2010WeeklyBimonthlyMonthlyNever4. Press the BACK button to save the settings and return to the home screen.5. If you want to exercise t

Strany 70 - 7.12 Time Setup

4-2010 7. OperationFIGURE 57. TIME SETUP SCREEN7.13 Load ManagementThe generator set may have been set up at installation to connect and disconnect ce

Strany 71 - 7.13 Load Management

7. Operation 4-20107.13.2 Manual Load ManagementCAUTION: To reduce unnecessary loss of service, it is highly recommended that manual loadmanagement be

Strany 72 - 7.13.2 Manual Load Management

8 Startup and Configuration8.1 Installation ReviewBefore starting the genset inspect the installation and check off each of the following questions if

Strany 73 - 8 Startup and Configuration

8. Startup and Configuration 4-2010If the situation occurs, close the main valve at the tank and vent the fuel from the line at thetank. After reconne

Strany 74 - 70 A029V088 (Issue 2)

4-2010 8. Startup and ConfigurationFIGURE 59. GENERATOR CONFIGURATION8.5 Transfer Switch ConfigurationTo configure the generator set for the transfer

Strany 75 - A029V088 (Issue 2) 71

8. Startup and Configuration 4-20102. Press and hold the blank button on the menu screen for at least 5 seconds to go to theConfig Menu.3. Press the u

Strany 76 - 72 A029V088 (Issue 2)

4-2010 8. Startup and ConfigurationFIGURE 60. TRANSFER SWITCH CONFIGURATION8.6 Transfer Switch Parameter AdjustmentsModel RSS100-6634 and RSS200-6635

Strany 77 - A029V088 (Issue 2) 73

8. Startup and Configuration 4-2010Model RSS100-6868 and RSS200-6869 Transfer Switches: To make transfer switchparameter adjustments:1. Press the MENU

Strany 78 - 74 A029V088 (Issue 2)

4-2010 8. Startup and ConfigurationFIGURE 61. TRANSFER SWITCH ADJUSTMENTS8.7 Generator Adjustments8.7.1 To Adjust the Output VoltageUse the following

Strany 79 - 8.7 Generator Adjustments

1. IMPORTANT SAFETY INSTRUCTIONS 4-20101.8.3 Only You Can Protect Yourself From CO Poisoning!· Locate the generator in an area where there are no wind

Strany 80 - 76 A029V088 (Issue 2)

8. Startup and Configuration 4-20102. With Output Volts selected on the Adjustments Menu screen, press the up or down arrowbutton to adjust the voltag

Strany 81 - Troubleshooting

9 Communication Troubleshooting9.1 In-Home Network Access to Generator SetTroubleshootingWARNING: Some Generator Set service procedures present hazard

Strany 82

9. Communication Troubleshooting 4-2010FIGURE 63. NETWORK CONNECTIONS (CONTROL BOARD AND ETHERNET CONNECTION)9.2 Remote Internet Access to Generator S

Strany 83 - A029V088 (Issue 2) 79

4-2010 9. Communication Troubleshooting7. Check to see if you can access a standard web page from a computer.· If not, contact the ISP to troubleshoot

Strany 84 - 80 A029V088 (Issue 2)

9. Communication Troubleshooting 4-20108. Verify with your ISP that the Static DNS (Domain Name Server) #1 and #2 are correct.9. If the previous steps

Strany 85 - A029V088 (Issue 2) 81

4-2010 9. Communication TroubleshootingFIGURE 65. GENERATOR SET HOME PAGEFIGURE 66. NETWORK SETUP - PAGE 2A029V088 (Issue 2) 81

Strany 86 - 82 A029V088 (Issue 2)

9. Communication Troubleshooting 4-2010FIGURE 67. NETWORK SETUP - PAGE 382 A029V088 (Issue 2)

Strany 87

Appendix A. Outline and System DrawingsTable of ContentsFigure 68. Wiring Diagram (Sheet 1 of 3) ...

Strany 88 - 84 A029V088 (Issue 2)

Appendix A. Outline and System Drawings 4-2010This page is intentionally blank.84 A029V088 (Issue 2)

Strany 89 - A029V088 (Issue 2) 85

4-2010 Appendix A. Outline and System DrawingsFIGURE 68. WIRING DIAGRAM (SHEET 1 OF 3)A029V088 (Issue 2) 85

Strany 90 - 86 A029V088 (Issue 2)

2 IntroductionImportant note for Brazil applications: The manufacturer warns that the installation, operationand maintenance of equipment by the user

Strany 91 - A029V088 (Issue 2) 87

Appendix A. Outline and System Drawings 4-2010FIGURE 69. WIRING DIAGRAM (SHEET 2 OF 3)86 A029V088 (Issue 2)

Strany 92 - FIGURE 71. HARNESS LABEL

4-2010 Appendix A. Outline and System DrawingsFIGURE 70. WIRING DIAGRAM (SHEET 3 OF 3)A029V088 (Issue 2) 87

Strany 93 - A029V088 (Issue 2) 89

Appendix A. Outline and System Drawings 4-2010FIGURE 71. HARNESS LABEL88 A029V088 (Issue 2)

Strany 94 - 90 A029V088 (Issue 2)

4-2010 Appendix A. Outline and System DrawingsFIGURE 72. HARNESS CONNECTIONS (SHEET 1 OF 4)A029V088 (Issue 2) 89

Strany 95 - A029V088 (Issue 2) 91

Appendix A. Outline and System Drawings 4-2010FIGURE 73. HARNESS CONNECTIONS (SHEET 2 OF 4)90 A029V088 (Issue 2)

Strany 96 - 92 A029V088 (Issue 2)

4-2010 Appendix A. Outline and System DrawingsFIGURE 74. WIRING HARNESS CONNECTIONS (SHEET 3 OF 4)A029V088 (Issue 2) 91

Strany 97 - FIGURE 76. OUTLINE DRAWING

Appendix A. Outline and System Drawings 4-2010FIGURE 75. WIRING HARNESS CONNECTIONS (SHEET 4 OF 4)92 A029V088 (Issue 2)

Strany 98 - 94 A029V088 (Issue 2)

4-2010 Appendix A. Outline and System DrawingsFIGURE 76. OUTLINE DRAWINGA029V088 (Issue 2) 93

Strany 99

Appendix A. Outline and System Drawings 4-2010This page is intentionally blank.94 A029V088 (Issue 2)

Komentáře k této Příručce

Žádné komentáře