CUMMINS N14 Specifikace Strana 474

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 587
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 473
Fuel Drain Line Restriction
Use Pressure Gauge, Part No. ST-1273, to measure fuel
drain line restriction.
NOTE: Do not measure fuel drain line restriction with the
fuel measuring device installed. This will not measure the
drain line restriction of the vehicle’s return plumbing.
Hold the gauge at the same level as the connection.
NOTE: The gauge will not measure the correct pressure if
the gauge is not held at the same level as the connection.
Operate the engine at maximum horsepower RPM and
Advertised Horsepower.
Observe the reading on the gauge.
NOTE: The maximum fuel drain line restriction for STC and
CELECT™ is as follows:
With Check Valves: 165 mm Hg [6.5 in Hg]
Without Check Valves: 65 mm Hg [2.5 in Hg]
Intake Manifold Pressure
Measure the intake manifold pressure (turbocharger
boost). Install pressure gauge, Part No. ST-1273, in the
intake manifold as shown.
Observe the reading on the pressure gauge.
General Test Procedure - Chassis Dynamometer (14-05) Engine Testing
N14Page 14-34
Zobrazit stránku 473
1 2 ... 469 470 471 472 473 474 475 476 477 478 479 ... 586 587

Komentáře k této Příručce

Jesus Morales 03 Apr 2025 | 23:07:31

Perfect..